Side-Power SEP 100/185 T Podręcznik Użytkownika Strona 1

Przeglądaj online lub pobierz Podręcznik Użytkownika dla Nie Side-Power SEP 100/185 T. Side-Power SEP 100/185 T User guide Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
Installasjons- og brukerveiledning
Made in Norway
©
Sleipner Motor AS 2014
SLEIPNER MOTOR AS
P.O. Box 519
N-1612 Fredrikstad
Norway
Tel: +47 69 30 00 60
Fax: +47 69 30 00 70
www.side-power.com
sidepower@sleipner.no
SRV(P) 80/185 T
SRL(P) 80/185 T
SRV(P) 100/185 T
SRL(P) 100/185 T
Installation & User Guide
EN
NO
SIDE-POWER
Thruster Systems
SRL SRV
Przeglądanie stron 0
1 2 3 4 5 6 ... 31 32

Podsumowanie treści

Strona 1 - SRL(P) 100/185 T

Installasjons- og brukerveiledningMade in Norway© Sleipner Motor AS 2014SLEIPNER MOTOR ASP.O. Box 519N-1612 FredrikstadNorwayTel: +47 69 30 00 60Fa

Strona 2 - DECLARATION OF CONFORMITY

10SRV(P)80/185T - SRL(P)80/185T - SRV(P)100/185T -SRL(P)100/185T 1.0.5 - Sept. 2014NOENMontering av overdel og lukeFitting the upper part & h

Strona 3 - SLEIPNER MOTOR AS

11SRV(P)80/185T - SRL(P)80/185T - SRV(P)100/185T -SRL(P)100/185T 1.0.5 - Sept. 2014Montering av elektromotorNOFitting the electromotorEN1. Rem

Strona 4

12SRV(P)80/185T - SRL(P)80/185T - SRV(P)100/185T -SRL(P)100/185T 1.0.5 - Sept. 2014Elektrisk installasjonNO• Forklaring til elektrisk tabell -

Strona 5 - Tekniske spesikasjoner

13SRV(P)80/185T - SRL(P)80/185T - SRV(P)100/185T -SRL(P)100/185T 1.0.5 - Sept. 2014B- (A1)++-Position sensorBattery12/24VMainFuseMainswitchS-l

Strona 6 - Positioning the thruster

14SRV(P)80/185T - SRL(P)80/185T - SRV(P)100/185T -SRL(P)100/185T 1.0.5 - Sept. 2014 

Strona 7

15SRV(P)80/185T - SRL(P)80/185T - SRV(P)100/185T -SRL(P)100/185T 1.0.5 - Sept. 2014

Strona 8

16SRV(P)80/185T - SRL(P)80/185T - SRV(P)100/185T -SRL(P)100/185T 1.0.5 - Sept. 2014VedlikeholdMaintenanceNOEN» Hold propellen og girhuset fritt

Strona 9 - LamineringMoulding

17SRV(P)80/185T - SRL(P)80/185T - SRV(P)100/185T -SRL(P)100/185T 1.0.5 - Sept. 2014Backbone cablesForms the main ”loop” around the boatPart #:

Strona 10 - Montering av overdel og luke

18SRV(P)80/185T - SRL(P)80/185T - SRV(P)100/185T -SRL(P)100/185T 1.0.5 - Sept. 2014Example of the control wiring with S-link system for boats wit

Strona 11 - Support for motor!

19SRV(P)80/185T - SRL(P)80/185T - SRV(P)100/185T -SRL(P)100/185T 1.0.5 - Sept. 2014PANEL ON: push both “ON” buttons simultaneously, thruster d

Strona 12 - 

2SRV(P)80/185T - SRL(P)80/185T - SRV(P)100/185T -SRL(P)100/185T 1.0.5 - Sept. 2014InnholdNOSAMSVARS ERKLÆRING Sleipner Motor AS Postboks

Strona 13 - 1.0.5 - Sept. 2014

20SRV(P)80/185T - SRL(P)80/185T - SRV(P)100/185T -SRL(P)100/185T 1.0.5 - Sept. 2014Hvordan bruke Side-Power trustereNHvordan bruke en baugtruster

Strona 14

21SRV(P)80/185T - SRL(P)80/185T - SRV(P)100/185T -SRL(P)100/185T 1.0.5 - Sept. 2014Signatur: ...

Strona 15 - A ( 0,32 : 1 )

22SRV(P)80/185T - SRL(P)80/185T - SRV(P)100/185T -SRL(P)100/185T 1.0.5 - Sept. 2014Important user precautionsEN• Forviss deg om at du kjenner pl

Strona 16 - Maintenance

23SRV(P)80/185T - SRL(P)80/185T - SRV(P)100/185T -SRL(P)100/185T 1.0.5 - Sept. 2014Before seeking assistance at the help desk of your Side-Pow

Strona 17 - Explaining S-link

24SRV(P)80/185T - SRL(P)80/185T - SRV(P)100/185T -SRL(P)100/185T 1.0.5 - Sept. 2014Problemer og løsningerNOFør du søker hjelp hos din forhandler

Strona 18 - 2 x 6 1321-xxM Spur cables

25SRV(P)80/185T - SRL(P)80/185T - SRV(P)100/185T -SRL(P)100/185T 1.0.5 - Sept. 2014Warranty statementEN1. The equipment manufactured by Sleipn

Strona 19 - Control panels

26SRV(P)80/185T - SRL(P)80/185T - SRV(P)100/185T -SRL(P)100/185T 1.0.5 - Sept. 2014Partslist -SRV(P)80/185T - SRL(P)80/185T - SRV(P)100/185T -SR

Strona 20 - PJC-212

27SRV(P)80/185T - SRL(P)80/185T - SRV(P)100/185T -SRL(P)100/185T 1.0.5 - Sept. 2014Partslist - SRV(P)80/185T - SRL(P)80/185T - SRV(P)100/185T

Strona 21 - Sjekkliste

28SRV(P)80/185T - SRL(P)80/185T - SRV(P)100/185T -SRL(P)100/185T 1.0.5 - Sept. 2014RevisionRevision Date CommentA 110814 Changed description of c

Strona 22 - Viktige brukerforbehold

29SRV(P)80/185T - SRL(P)80/185T - SRV(P)100/185T -SRL(P)100/185T 1.0.5 - Sept. 2014Notes

Strona 23 - Troubleshooting

3SRV(P)80/185T - SRL(P)80/185T - SRV(P)100/185T -SRL(P)100/185T 1.0.5 - Sept. 2014Measurements, thrusterENMålskisse, trusterNO112233445566A AB

Strona 24 - Problemer og løsninger

30SRV(P)80/185T - SRL(P)80/185T - SRV(P)100/185T -SRL(P)100/185T 1.0.5 - Sept. 2014Notes

Strona 25 - Warranty statement

31SRV(P)80/185T - SRL(P)80/185T - SRV(P)100/185T -SRL(P)100/185T 1.0.5 - Sept. 2014Notes

Strona 26 - -SRL(P)100/185T

Worldwide sales and servicewww.side-power.comSLEIPNER MOTOR AS P.O. Box 519 N-1612 Fredrikstad NorwayTel: +47 69 30 00 60 Fax:+47 69 30 00 70

Strona 27 - 12V 24V 12V 24V Pcs

4SRV(P)80/185T - SRL(P)80/185T - SRV(P)100/185T -SRL(P)100/185T 1.0.5 - Sept. 2014Viktige forholdsregler og planlegningNFør installasjon må instr

Strona 28 - Revision Date Comment

5SRV(P)80/185T - SRL(P)80/185T - SRV(P)100/185T -SRL(P)100/185T 1.0.5 - Sept. 2014TYPESRV/SRL Thruster med en hastighetTYPE SRVP/SRLP: Thru

Strona 29

6SRV(P)80/185T - SRL(P)80/185T - SRV(P)100/185T -SRL(P)100/185T 1.0.5 - Sept. 2014NOENPlassering av enhetenPositioning the thrusterEnten thruster

Strona 30

7SRV(P)80/185T - SRL(P)80/185T - SRV(P)100/185T -SRL(P)100/185T 1.0.5 - Sept. 201429.03.2012Designed byDateEditionSheetTore Eriksen Material T

Strona 31

8SRV(P)80/185T - SRL(P)80/185T - SRV(P)100/185T -SRL(P)100/185T 1.0.5 - Sept. 2014NOENPlassering av enheten (forts.)Positioning the thruster (con

Strona 32 - Worldwide sales and service

9SRV(P)80/185T - SRL(P)80/185T - SRV(P)100/185T -SRL(P)100/185T 1.0.5 - Sept. 2014NOENLamineringMouldingEnheten er nå i riktig posisjon og er

Komentarze do niniejszej Instrukcji

Brak uwag